CustomProperty
Gears - Thermal capacity - Part 1: Rating gear drives with thermal equilibrium at 95 oC sump temperature

ISO/TR 14179-1:2001

ISO/TR 14179-1:2001
This part of ISO/TR 14179 utilizes an analytical heat balance model to provide a means of calculating the thermal
transmittable power of a single- or multiple-stage gear drive lubricated with mineral oil. The calculation is based on
standard conditions of 25°C maximum ambient temperature and 95 °C maximum oil sump temperature in a large
indoor space, but provides modifiers for other conditions.